Valve Pulse
Rate at which the valve dispenses shot. The Valve Pulse
is factory set to match the best ow characteristics of
the media (cast steel or cut wire). The typical operation
rate is 8 Hertz.
Test Connector
Provides access to
diagnostic voltages.
• 0 - 10 Vdc input
• 24 Vdc “Enable input
• 6 - 20 Hertz pulse rate
• 0 Vdc common
Operation
Remote Valve Driver
Valve Driver Panel (behind the cover plate)
*Diagnostic LEDs
Valve On. Indicates when power is being sent to the MagnaValve’s electromagnet. When the
LED is on, the valve is on for full capacity ow rate. When the LED is o, the MagnaValves
permanent magnet has stopped the media ow. When the LED is blinking, the shot ow is
being regulated.
Vin > 0.25 Vdc. Indicates that an analog signal input greater than 0.25 Vdc has been received.
When this LED is o, no media ow is allowed. The input signal range is 0 -10 Vdc. At 10 Vdc,
the MagnaValve will open to full capacity. The relationship between the 0 -10 Vdc input signal
and actual ow rate is non-linear.
24 Vdc Enable. Indicates that the 24 Vdc Enable Signal has been received. When the LED is
o, the MagnaValve is inhibited and no shot will ow. This feature is provided as an on-o
action so the 0-10 Vdc input signal does not have to be disabled or removed.
24 Vdc Power. Indicates that 24 Vdc is available to operate the electromagnet for media ow.
It should always be available and able to supply 2 Amps.
All four LEDs must be on in order to have media ow.
Diagnostic LEDs*
The large knurled screw on the front cover of the Remote Valve Driver can be removed to gain
access to the factory adjustments. Please refer all adjustments to qualied personnel.